Magnetics Calculators29 instruments

Helmholtz Coil

Coil pair spacing for maximally uniform field; explore d ≠ R.

B=(45)3/2μ0NIRB=\left(\tfrac45\right)^{3/2}\frac{\mu_0NI}{R}
Fig. 1 Coaxial coil pair: at d = R the field is maximally flat in the middle
d = 1 Runiform regionR = 100 mm · N = 100 per coil
Fig. 2 Axial field: each coil (dashed) and the sum
-200-10001002000200400600800z (mm)B (µT)
totalcoil 1coil 2
hover / touch plot to probe
Inputs drag, tap ± or type (SI suffixes ok: 4k7 → 4.7k)
A
mm
Results
BB at centre
899.2 µT
Ideal Helmholtz (d=R)
899.2 µT
±1 % uniform zone
±30 mm30 % of R
Coil constant
899 µT/A
Configuration
Helmholtz ✓

§ How it works

Two identical coaxial loops separated by dd each produce the single-loop field; on the axis they simply add:

B(z)=μ0NIR22[1(R2+(z−d2)2)3/2+1(R2+(z+d2)2)3/2]B(z) = \frac{\mu_0 N I R^2}{2}\left[\frac{1}{\left(R^2+(z-\tfrac d2)^2\right)^{3/2}} + \frac{1}{\left(R^2+(z+\tfrac d2)^2\right)^{3/2}}\right]

By symmetry all odd derivatives vanish at z=0z=0. Choosing d=Rd = R also makes the second derivative zero, so the first non-zero error term is fourth-order, so the field is remarkably flat. Then the centre field is

B0=(45)3/2μ0NIR≈0.7155 μ0NIRB_0 = \left(\tfrac45\right)^{3/2}\frac{\mu_0 N I}{R} \approx 0.7155\,\frac{\mu_0 N I}{R}

Try sliding d/Rd/R: below 1 the field peaks in the centre, above 1 it dips. Helmholtz coils are used to null Earth's field, calibrate magnetometers and in e/m experiments.