§ How it works
An inductor opposes changes of current: . For a sinusoid the voltage is , leading the current by 90°, with amplitude ratio
Real inductors have winding resistance (ESR), so the phase is less than 90°. The quality factor compares energy stored to energy lost per radian; high-Q coils make sharp filters and efficient resonators. At very high frequency the winding's self-capacitance eventually causes self-resonance (not modelled here).
Energy stored in the magnetic field is ; it sloshes between source and inductor twice per cycle, which is the reactive power .