Magnetics Calculators29 instruments

Current Loop Axial Field

Biot–Savart on the axis of a circular coil and its dipole limit.

B=μ0NIR22(R2+z2)3/2B=\frac{\mu_0 NIR^2}{2(R^2+z^2)^{3/2}}
Fig. 1 Current loop in perspective with the on-axis probe point P
Pz = 30 mmR = 50 mmN = 10, I = 1 Am = NIπR² = 78.5 mA·m²
Fig. 2 Field along the axis vs. far-field dipole approximation
-200-1000100200020406080100120z (mm)B (µT)
exactdipole
hover / touch plot to probe
Inputs drag, tap ± or type (SI suffixes ok: 4k7 → 4.7k)
A
mm
mm
Results
BB at P
79.23 µT
BB at centre
125.7 µT
Ratio B(z)/B(0)B(z)/B(0)
0.6305
Dipole approximation
582 µTinaccurate near the loop
Magnetic moment mm
78.5 mA·m²

§ How it works

Integrating the Biot–Savart law dB=μ0I4πdℓ×r^r2d\mathbf B = \frac{\mu_0 I}{4\pi}\frac{d\boldsymbol\ell\times\hat{\mathbf r}}{r^2} around a ring, the radial components cancel by symmetry and only the axial part survives:

Bz(z)=μ0NIR22(R2+z2)3/2,B(0)=μ0NI2RB_z(z) = \frac{\mu_0 N I R^2}{2\left(R^2+z^2\right)^{3/2}},\qquad B(0) = \frac{\mu_0 N I}{2R}

Far from the loop (z≫Rz \gg R) this becomes the field of a magnetic dipole with moment m=NIπR2m = NI\pi R^2:B≈μ0m2πz3B \approx \frac{\mu_0 m}{2\pi z^3}. The cubic decay is why small coils and magnets lose influence so rapidly with distance.

The field at the centre is the starting point for Helmholtz pairs, MRI gradient coils and search coils for magnetometry.