Magnetics Calculators29 instruments

Air-Core Solenoid Inductance

Wheeler & Nagaoka corrected inductance of single-layer coils.

L=μ0N2Aℓ+0.9rL=\frac{\mu_0 N^2A}{\ell+0.9r}
Fig. 1 Single-layer coil, side view: flux returns around the outside
NSℓ = 30 mmDN = 40 turns · pitch 0.75 mm
Fig. 2 Inductance vs. winding length (same N, D)
0204060801001201010016.2 µHwinding length ℓ (mm)L (µH)
Wheelerideal μ₀N²A/ℓ
hover / touch plot to probe
Inputs drag, tap ± or type (SI suffixes ok: 4k7 → 4.7k)
mm
mm
Core
Hz
A
Results
Inductance (Wheeler)
16.2 µH
Long-solenoid ideal
21.06 µHignores end effects
Nagaoka factor KK
0.769
Aspect ℓ/D\ell / D
1.5ok
Wire length
2.51 m
Max wire Ø (close wound)
750 µm
Bore field B0B_0
697 µTcentre, Biot–Savart
Reactance XLX_L
102 Ω
Unloaded Q
7,570Rac ≈ 13.4 mΩ
SRF estimate
59.7 MHz≈150/wire-length

§ How it works

For an infinitely long solenoid the field inside is uniform, B=μ0μrNI/ℓB = \mu_0 \mu_r N I/\ell, and every turn links the same flux Φ=BA\Phi = BA. Flux linkage λ=NΦ\lambda = N\Phi divided by current gives the textbook result:

Lideal=μ0μrN2Aℓ,A=πD24L_{ideal} = \frac{\mu_0 \mu_r N^2 A}{\ell}, \qquad A = \frac{\pi D^2}{4}

Real coils are finite: field lines spread out at the ends, so outer turns link less flux. Nagaoka captured this with a correction coefficient K≤1K \le 1, L=K LidealL = K\,L_{ideal}. Harold Wheeler's 1928 empirical fit gives an excellent closed form (≈1 % for ℓ>0.4D\ell > 0.4D):

L≈μ0μrN2Aℓ+0.9 r    ⟺    L[μH]=r2N29r+10ℓ  (inches)L \approx \frac{\mu_0 \mu_r N^2 A}{\ell + 0.9\,r} \;\;\Longleftrightarrow\;\; L[\mu H] = \frac{r^2 N^2}{9r + 10\ell}\;\text{(inches)}

The plot shows why: as the coil gets shorter, the ideal formula diverges (∝1/ℓ\propto 1/\ell) while the real inductance saturates. Inductance scales with N2N^2: doubling the turns quadruples LL. A ferrite rod raises inductance by its effective permeability, which for an open rod is far below the material's μr\mu_r because most of the path is still air.