Magnetics Calculators29 instruments

Rotating Coil Generator

Faraday induction: EMF from turns, field, area and rpm.

E=NBAωsin⁡ωt\mathcal E=NBA\omega\sin\omega t
Fig. 1 Rotating coil between pole pieces (end view) and the induced EMF
NSΦ ∝ cos ωt = 1EMF (peak 31.4 V)flux ΦEMF is maximal when flux is passing through zeroanimation slowed to 0.5 rev/s
Fig. 2 Peak EMF vs. rotational speed
02k4k6k8k10k020406080100speed (rpm)E_pk (V)
E_pk
hover / touch plot to probe
Inputs drag, tap ± or type (SI suffixes ok: 4k7 → 4.7k)
T
cm²
rpm
Ω
Results
Peak EMF EpkE_{pk}
31.42 V
RMS EMF
22.21 V
Output frequency
50 Hz
Angular speed ω\omega
314.2 rad/s
Power into R (ideal)
49.3 W
Peak flux linkage NΦN\Phi
100 mWb

§ How it works

Faraday's law: a changing flux linkage induces an EMF, E=−dλdt\mathcal E = -\frac{d\lambda}{dt}. A flat coil rotating at angular speed ω\omega in uniform field BB links flux

λ(t)=NBAcos⁡ωt  ⇒  E(t)=NBA ωsin⁡ωt,Erms=NBAω2\lambda(t) = N B A\cos\omega t \;\Rightarrow\; \mathcal E(t) = N B A\,\omega\sin\omega t,\qquad E_{rms} = \frac{NBA\omega}{\sqrt2}

The EMF peaks when the coil plane is parallel to the field (flux crossing zero, changing fastest) and vanishes when it faces the poles. EMF scales linearly with each of NN, BB, AA and speed (the generator constant). The Lenz minus sign means the induced current opposes the motion, so the power delivered to the load must be supplied as mechanical torque.

Ignores coil resistance and inductance; a real alternator's terminal voltage sags under load.