§ How it works
The magnetic circuit is coil → iron → gap → armature → gap → iron. With the armature reluctance lumped into the iron path, the gap flux density is
The attractive force comes from the magnetic pressure (Maxwell stress) acting on every pole face:
At 1 T the pressure is about 4 bar (398 kPa). Force rises with as the gap closes, until the iron saturates and the curve flattens, so a clean, flat contact surface matters far more than extra amp-turns. Real magnets lose some force to leakage and fringing, so treat the result as an upper bound.