Magnetics Calculators29 instruments

Electromagnet Holding Force

Maxwell pressure on pole faces vs. air gap with saturation.

F=B2A2μ0F=\frac{B^2A}{2\mu_0}
Fig. 1 U-core lifting magnet with armature: two pole faces, two gaps
415 Ngap 0.2 mm × 2NI = 500 A·t · pole face 400 mm² each
Fig. 2 Holding force vs. air gap (saturation plateau at small gaps)
0.010.11100.1110100gap g (mm)F (N)
F
hover / touch plot to probe
Inputs drag, tap ± or type (SI suffixes ok: 4k7 → 4.7k)
A
mm
mm²
mm
T
Results
Holding force
415.4 N
Lifting capacity
42.4 kgbefore safety factor
Gap flux density BB
1.14 T
Pressure on face
519 kPa
Ampere-turns to saturate
700.3 A·t

§ How it works

The magnetic circuit is coil → iron → gap → armature → gap → iron. With the armature reluctance lumped into the iron path, the gap flux density is

B=μ0NI2g+ℓFe/μr(≤Bsat)B = \frac{\mu_0 N I}{2g + \ell_{Fe}/\mu_r}\quad (\le B_{sat})

The attractive force comes from the magnetic pressure (Maxwell stress) p=B2/2μ0p = B^2/2\mu_0 acting on every pole face:

F=npoles B2A2μ0F = n_{poles}\,\frac{B^2 A}{2\mu_0}

At 1 T the pressure is about 4 bar (398 kPa). Force rises with 1/g21/g^2 as the gap closes, until the iron saturates and the curve flattens, so a clean, flat contact surface matters far more than extra amp-turns. Real magnets lose some force to leakage and fringing, so treat the result as an upper bound.