Magnetics Calculators29 instruments

Winding Window Fill (Ku)

Layer packing, fill factor, DC resistance and copper loss in a bobbin.

Ku=NACuWaK_u=\frac{NA_{Cu}}{W_a}
Fig. 1 Bobbin window 19 × 6.8 mm: 3 layers × 17/layer, build 3.43 mm
copper = bare Ø 1 mm (≈ AWG 18) · outer Ø 1.09 mm
Fig. 2 Bare fill factor vs. turns (for this wire + window)
02040608000.10.20.30.40.5turns NKu bare
Ku
hover / touch plot to probe
Inputs drag, tap ± or type (SI suffixes ok: 4k7 → 4.7k)
mm
mm
mm
A
mm
Results
Bare fill Ku,bareK_{u,bare}
29.2 %Ku = 0.292 (target 0.30–0.50)
Packed fill Ku,packedK_{u,packed}
44.1 %3 layers fit cleanly
DC resistance
63.2 mΩwire 2.88 m
Copper loss
1.12 WI²R
Current density
5.35 A/mm²

§ How it works

Round wire never fills a rectangular window completely (π/4 ≈ 78.5 % even before insulation, tape and creepage). The bare-copper fill factor is:

Ku,bare=N πdbare2/4WwHw,Nlayers=⌈N⌊Ww/dins⌋⌉K_{u,bare}=\frac{N\,\pi d_{bare}^2/4}{W_w H_w}, \qquad N_{layers}=\left\lceil\frac{N}{\lfloor W_w/d_{ins}\rfloor}\right\rceil
Rdc=ρCuN⋅MLTACu,PCu=Irms2RdcR_{dc}=\rho_{Cu}\frac{N\cdot\mathrm{MLT}}{A_{Cu}}, \qquad P_{Cu}=I_{rms}^2 R_{dc}

Practical single windings reach Ku ≈ 0.45–0.55, multi-winding transformers 0.30–0.40, Litz/TIW safety windings 0.20–0.28. Leave 10–15 % height for outer tape, and subtract margin tape from Ww before counting turns per layer.