Magnetics Calculators29 instruments

Transformer Core Area Product

McLyman Ap sizing from throughput power with standard core matcher.

Ap=PtkfKuBfJA_p=\frac{P_t}{k_fK_uBfJ}
Fig. 1 Standard ferrite cores vs. required area product: first core above the amber line wins
Required Ap = 0.372 cm⁴ → ETD29Pt = 516 VA at η = 94 % · J·Ku = 1.57 A/mm²EE160.06EE250.36ETD290.93ETD341.61ETD392.93ETD444.82ETD497.51E55/2813.3E65/3228.5required 0.372 cm⁴
Fig. 2 Required Ap vs. frequency (doubling f halves the core)
205010020050000.511.5frequency (kHz)Ap (cm⁴)
Ap
hover / touch plot to probe
Inputs drag, tap ± or type (SI suffixes ok: 4k7 → 4.7k)
Waveform factor kf
W
kHz
T
A/mm²
Results
Required area product ApA_p
0.3723 cm⁴= 3723 mm⁴
Recommended core
ETD29 (0.93 cm⁴)Ae = 76 mm² · Wa = 123 mm²
Apparent power PtP_t
516 VA
Window power density J·Ku
1.57 A/mm²

§ How it works

A transformer's voltage capability scales with iron area AeA_e (Faraday) and its current capability with window area WaW_a. Their product is McLyman's area product:

Ap=WaAe=Pt×104kfKuBmaxfJ    [cm4]A_p = W_a A_e = \frac{P_t \times 10^4}{k_f K_u B_{max} f J}\;\;[\mathrm{cm^4}]

Total apparent power Pt=Pout(1+1/η)P_t = P_{out}(1+1/\eta) covers primary plus secondary VA (η ≈ 0.94). JJ is in A/cm² inside the formula (A/mm² × 100). Doubling ff halves the required core.

Pick the first standard core with Ap≥Ap,reqA_p \ge A_{p,req}, then verify Steinmetz core loss plus copper loss fits a ~40 °C rise. For triple-insulated safety secondaries use Ku ≈ 0.22–0.30.