Magnetics Calculators29 instruments

DC-DC Converter Inductor

Buck/boost/buck-boost ripple ΔIL, RMS, peak energy and CCM/DCM boundary.

ΔIL=VonDfswL\Delta I_L=\frac{V_{on}D}{f_{sw}L}
Fig. 1 Buck / boost / buck-boost inductor: volt-second balance sets the ripple
Buck (step-down) · D = 50 %Tsw = 5 µs · Imin = 4 AIL,avg = 5 AIpk = 6 A · ΔIL = 2 A p-pCCM (L > Lcrit 3 µH)
Fig. 2 Inductor current over two switching cycles (triangular ripple)
02468100123456time (µs)IL (A)
IL
hover / touch plot to probe
Fig. 3 Ripple ratio vs. inductance (design curve, 20–40 % band ideal)
102030405010015020020%40%L (µH)ripple r (%)
r
hover / touch plot to probe
Inputs drag, tap ± or type (SI suffixes ok: 4k7 → 4.7k)
Topology
V
V
µH
Hz
A
Results
Ripple current ΔIL\Delta I_L
2 Ar = 40 % of IL,avg (target 20–40 %)
Peak current IpkI_{pk}
6 Amust stay below inductor Isat
RMS current IrmsI_{rms}
5.03 Aaverage 5 A
Stored peak energy
270 µJ½LIpk²
Duty cycle
50 %VL,on = 12 V · VL,off = -12 V
CCM boundary Lcrit
3 µHabove boundary → CCM

§ How it works

The inductor obeys VL=L dIL/dtV_L = L\,dI_L/dt. During the on-time ton=D/fswt_{on}=D/f_{sw} a nearly constant voltage VL,onV_{L,on} ramps the current up by:

ΔIL=VL,on Dfsw L,Ipk=IL,avg+ΔIL2\Delta I_L = \frac{V_{L,on}\,D}{f_{sw}\,L}, \qquad I_{pk} = I_{L,avg}+\frac{\Delta I_L}{2}

Duty and average inductor current depend on topology (ideal CCM): buck D=Vout/Vin,  IL,avg=IoutD=V_{out}/V_{in},\; I_{L,avg}=I_{out}; boost D=1−Vin/Vout,  IL,avg=Iout/(1−D)D=1-V_{in}/V_{out},\; I_{L,avg}=I_{out}/(1-D); buck-boost D=Vout/(Vin+Vout),  IL,avg=Iout/(1−D)D=V_{out}/(V_{in}+V_{out}),\; I_{L,avg}=I_{out}/(1-D).

Irms=IL,avg2+ΔIL2/12,Epk=12LIpk2,Lcrit=VL,onD2fswIL,avgI_{rms}=\sqrt{I_{L,avg}^2+\Delta I_L^2/12}, \qquad E_{pk}=\tfrac12 L I_{pk}^2, \qquad L_{crit}=\frac{V_{L,on}D}{2 f_{sw} I_{L,avg}}

Target a ripple ratio r=ΔIL/IL,avg≈20–40%r=\Delta I_L/I_{L,avg}\approx 20\text{–}40\%. Below ~20 % the inductor is oversized and slow; above ~50 % peak core loss, saturation headroom and output-capacitor ripple current all suffer. When L < Lcrit the valley hits zero and the converter enters discontinuous (DCM) mode.