Magnetics Calculators29 instruments

Reluctance Network (Hopkinson)

Lumped magnetic circuit: flux, MMF drops and gap dominance.

Φ=NIRc+Rg\Phi=\frac{NI}{\mathcal R_c+\mathcal R_g}
Fig. 1 Hopkinson's law: MMF source ℱ = NI driving flux Φ through ℛcore + ℛgap
ℱ = NI250 Atℛcore = 318 kH⁻¹Δℱcore = 14.15 At (5.66 %)ℛgap5.31 MH⁻¹Φ = 44.5 µWb · Δℱgap = 235.8 At (94.3 %)ℛgap/ℛcore = 16.7× · L = N²/ℛ = 1.78 mH
Fig. 2 Inductance and flux density vs. gap (gap dominates ℛ)
0.010.1101000200030004000gap (mm)L (mH) / B (T)
L (mH)B (mT)
hover / touch plot to probe
Inputs drag, tap ± or type (SI suffixes ok: 4k7 → 4.7k)
A
mm
mm
mm²
Results
Flux Φ\Phi
44.5 µWbB = 296 mT
Gap reluctance Rgap\mathcal R_{gap}
5.31 MH⁻¹94.3 % of MMF
Core reluctance Rcore\mathcal R_{core}
318 kH⁻¹5.66 % of MMF
MMF
250 At
Inductance N²/ℛ
1.78 mH

§ How it works

Hopkinson's law is Ohm's law for magnetics: MMF F=NI\mathcal F = NI drives flux ΦΦ through reluctance R=l/(μ0μrA)\mathcal R = l/(\mu_0\mu_r A):

F=NI=Φ (Rcore+Rgap),Rcore=lcμ0μrAc,    Rgap=lgμ0Ac\mathcal F = NI = \Phi\,(\mathcal R_{core}+\mathcal R_{gap}), \qquad \mathcal R_{core}=\frac{l_c}{\mu_0\mu_r A_c},\;\; \mathcal R_{gap}=\frac{l_g}{\mu_0 A_c}

A 1 mm air gap has the reluctance of ~2 m of ferrite (μr ≈ 2000), so almost all MMF drops across the gap. Designing with Rgap≫Rcore\mathcal R_{gap}\gg\mathcal R_{core} makes L=N2/RL=N^2/\mathcal R immune to ±25 % ferrite μr spreads, at the cost of lower inductance per turn.