Magnetics Calculators29 instruments

RL Filter Bode Plot

Low/high-pass cut-off, magnitude and phase response.

fc=R2πLf_c=\frac{R}{2\pi L}
Fig. 1 Series L, shunt R: first-order low-pass
VᵢₙVₒL = 1 mHR = 100 Ωf_c = 15.9 kHz · τ = 10 µs
Fig. 2 Bode magnitude with asymptotes (−20 dB/decade)
1k100k10M-60-50-40-30-20-100f_c (−3 dB)frequency (Hz)gain (dB)
asymptote|H|
hover / touch plot to probe
Fig. 3 Bode phase
1k100k10M-80-60-40-200frequency (Hz)phase (°)
∠H
hover / touch plot to probe
Inputs drag, tap ± or type (SI suffixes ok: 4k7 → 4.7k)
Filter type
Ω
H
Hz
Results
Cut-off fcf_c
15.92 kHz
Time constant τ\tau
10 µs
Gain at ff
-1.445 dB|H| = 0.8467
Phase at ff
-32.14°
XLX_L at ff
62.8 Ω

§ How it works

The inductor's impedance ZL=jωLZ_L = j\omega L grows with frequency, so the voltage divider between LL and RR becomes frequency-selective:

HLP(jω)=RR+jωL=11+j f/fc,HHP(jω)=j f/fc1+j f/fc,fc=R2πLH_{LP}(j\omega) = \frac{R}{R + j\omega L} = \frac{1}{1 + j\,f/f_c},\qquad H_{HP}(j\omega) = \frac{j\,f/f_c}{1 + j\,f/f_c},\qquad f_c = \frac{R}{2\pi L}

At fcf_c the reactance equals the resistance, the gain is 1/21/\sqrt2 (−3.01 dB) and the phase is −45° (or +45°). Far from fcf_c the response follows straight asymptotes with slope ±20 dB/decade (±6 dB/octave), the hallmark of a first-order (single-pole) system.

The same pole appears in the time domain as the time constant τ=L/R=1/(2πfc)\tau = L/R = 1/(2\pi f_c). RL low-pass sections are common in power-supply output filters and EMI chokes, where an inductor passes DC with minimal loss.