Magnetics Calculators29 instruments

RL Time Constant

Step response of an inductor, with animated oscilloscope.

τ=L/R\tau=L/R
Fig. 1 Switched RL circuit and live oscilloscope trace
i / I₀ = 0switch closes at t = 0Vi(t)v_L(t)grid = 1τ = 10 ms
Fig. 2 Current and inductor voltage vs. time
00.010.020.030.040.050246810121τ2τ3τ4τ63.2 %time (s)i (A) / v_L (V)
i(t) [A]v_L(t) [V]
hover / touch plot to probe
Inputs drag, tap ± or type (SI suffixes ok: 4k7 → 4.7k)
Event
V
Ω
H
Results
Time constant τ=L/R\tau = L/R
10 ms
Final current I0=V/RI_0 = V/R
1.2 A
Time to 63.2 % / 95 % / 99 %
10 ms / 30 ms / 46 ms
Initial di/dtdi/dt
120 A/s
Stored energy 12LI02\tfrac12 L I_0^2
72 mJ

§ How it works

Kirchhoff's voltage law around the loop gives a first-order differential equation, V=iR+LdidtV = iR + L\frac{di}{dt}. Its solutions are exponentials with time constant τ=L/R\tau = L/R:

on: i(t)=VR(1−e−t/τ),vL=Ve−t/τoff: i(t)=I0 e−t/τ\text{on: } i(t) = \frac{V}{R}\left(1 - e^{-t/\tau}\right),\quad v_L = V e^{-t/\tau}\qquad \text{off: } i(t) = I_0\,e^{-t/\tau}

An inductor resists sudden changes of current: at t=0+t=0^+ the full source voltage appears across it and the current starts rising at V/LV/L. After one τ\tau the current reaches 63.2 %, after 5τ5\tau it is within 1 % of the final value.