Magnetics Calculators29 instruments

Skin Depth & AC Resistance

Current crowding vs. frequency for common conductors.

δ=ρπfμ\delta=\sqrt{\frac{\rho}{\pi f\mu}}
Fig. 1 Current density across the wire cross-section (bright = more current)
Ø 1 mm copper wireJ(depth) / J(surface)δ (1/e)surfacecentre
Fig. 2 Skin depth vs. frequency (dashed: wire radius)
100100k100M0.0000010.000010.00010.0010.01wire radiusfrequency (Hz)δ (m)
Copper
hover / touch plot to probe
Inputs drag, tap ± or type (SI suffixes ok: 4k7 → 4.7k)
Hz
mm
mm
Results
Skin depth δ\delta
206.3 µm
Rac/RdcR_{ac}/R_{dc}
1.527
DC resistance
21.4 mΩ/m
AC resistance
32.7 mΩ/m
Frequency where δ=r\delta = r
17 kHzabove this, use Litz or thinner strands
Max useful strand Ø (≈ 2δ)
413 µm
Dowell FRF_R (m layers)
28×Δ = deff/δ = 4.3 · single-layer 4.3×
Litz estimate
1.03×100 strands Ø 0.1 mm

§ How it works

An alternating current creates an alternating magnetic field inside the conductor, which induces eddy currents that oppose the current at the centre and reinforce it near the surface. Solving the diffusion equation gives an exponentially decaying current density J(x)=Jse−x/δJ(x) = J_s e^{-x/\delta} with

δ=ρπfμ0μr=2ρωμ\delta = \sqrt{\frac{\rho}{\pi f \mu_0 \mu_r}} = \sqrt{\frac{2\rho}{\omega\mu}}

For copper this is about 66 mm/f66\,\text{mm}/\sqrt{f}: 9.3 mm at 50 Hz, 0.21 mm at 100 kHz, 6.6 µm at 100 MHz. Ferromagnetic conductors (steel) have much smaller skin depths because of their high μr\mu_r.

The resistance estimate treats the current as flowing uniformly in an annulus of thickness δ\delta:Rac/Rdc=r2/(r2−(r−δ)2)R_{ac}/R_{dc} = r^2 / \left(r^2-(r-\delta)^2\right), accurate for r≳2δr \gtrsim 2\delta. In multi-layer windings the proximity effect adds further loss (see Dowell's method).