Magnetics Calculators29 instruments

Core Loss (Steinmetz)

Volumetric loss of ferrite, steel & nanocrystalline cores.

Pv=kfαBβP_v=kf^\alpha B^\beta
Fig. 1 Core heating indicator: volumetric loss turned into colour
E-core, Vₑ = 5 cm³loss density1 kW/m³3 MW/m³66.4 kW/m³= 66.41 mW/cm³total 332 mW
Fig. 2 Loss density vs. peak flux at ¼f, f and 4f
0.010.11100m101k100kpeak B (T)P_v (kW/m³)
25 kHz100 kHz400 kHz
hover / touch plot to probe
Inputs drag, tap ± or type (SI suffixes ok: 4k7 → 4.7k)
Hz
T
cm³
cm²
°C
Results
Core loss
332 mW
Loss density PvP_v
66.41 kW/m³66.41 mW/cm³
Energy per cycle
664 mJ/m³
Loss ×2 if f doubles
×2.64
Loss ×2 if B doubles
×5.66
Temperature rise
+8.6 °Ccore ≈ 33.6 °C
Presets are representative curve fits for exploration; always use your exact material's datasheet coefficients.

§ How it works

Charles Steinmetz observed in 1892 that hysteresis loss in iron follows a power law. Generalised to include eddy-current and residual losses, the Steinmetz equation is

Pv=k fα B^β[W/m3],P=PvVeP_v = k\,f^{\alpha}\,\hat B^{\beta}\qquad [\mathrm{W/m^3}],\qquad P = P_v V_e

kk, α\alpha and β\beta are fitted to the manufacturer's loss curves over a limited range of frequency, flux and temperature. Typically 1<α<21 < \alpha < 2 (1 = pure hysteresis, 2 = pure eddy currents) and 2<β<32 < \beta < 3. Here ff is in Hz and B^\hat B in tesla.