§ How it works
Ferromagnets remember: domain walls snag on defects, so the magnetisation lags the applied field and traces a loop. Key points are saturation , remanence (flux left at ) and coercivity (reverse field needed to bring to zero).
This tool uses a phenomenological tanh model, with branches shifted so the loop closes at the drive amplitude :
The energy dissipated per cycle and unit volume equals the enclosed area, , computed numerically. Multiply by frequency for loss power: . Reducing the drive amplitude produces narrower minor loops: the reason Steinmetz's exponent exceeds 1.
Soft materials (transformer steel, ferrite, permalloy) have thin loops to minimise loss; hard materials (Alnico, NdFeB) have fat loops to retain magnetisation.